Showing all 10 results
- SKU:MLLG-AG-LED-IMF-200-5-[Optic]-TR-[V] | Web ID:1653100V-277V Standard Finish:240 In StockShips 2-3 Days277V-480V Standard Finish:Built to Order 8 Weeks100V-277V Marine Grade:Built to Order 8 Weeks
- Watts: 200
- Lumens: 28000
- Lumens/Watt: 140
- Replaces: 400 Watt Metal Halide
- Color Temp: 4000K | 5000K
- CRI: 70+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V
- Surge Protection: 6kV line-line, 10kV line-earth
- Operating Temp: -22°F to 113°F (-30°C to 45°C)
- Rated Life: 176,000 (L70) hours
- Dimmable: 1-10V
- Beam Angle: 60°(std), 10°, 15°, 30°, 45°, 40*100°
- Optics: Polycarbonate Optics and Tempered Glass Lens
- Housing: Powder Coated Aluminum
- Fixture Color: Gray
- Mount: Slip Fitter | Trunnion
- EPA Rating: 1.36
- Dimensions: 12 in L x 4.7 in W x 12.7 in H
- Cord Length: 5 Feet
- Weight: 13 lbs
Starting At$294.17 - SKU:MLLG-AG-LED-IMF-400-5-[Optic]-TR-[V] | Web ID:1654100V-277V Standard Finish:189 In StockShips 2-3 Days277V-480V Standard Finish:119 In StockShips 2-3 Days100V-277V Marine Grade:Built to Order 8 Weeks
- Watts: 400
- Lumens: 56000
- Lumens/Watt: 140
- Replaces: 1000 Watt Metal Halide
- Color Temp: 4000K | 5000K
- CRI: 70+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V
- Surge Protection: 6kV line-line, 10kV line-earth
- Operating Temp: -22°F to 113°F (-30°C to 45°C)
- Rated Life: 176,000 (L70) hours
- Dimmable: 1-10V
- Beam Angle: 60°(std), 10°, 15°, 30°, 45°
- Optics: Polycarbonate Optics and Tempered Glass Lens
- Housing: Powder Coated Aluminum
- Fixture Color: Gray
- Mount: Slip Fitter | Trunnion
- EPA Rating: 1.89
- Dimensions: 13.25 in L x 6.3 in W x 17.4 in H
- Cord Length: 5 Feet
- Weight: 24 lbs
Starting At$564.42 - SKU:MLLG-AG-LED-IMF-600-5-[Optic]-TR-[V] | Web ID:1655100V-277V:8 In StockShips 2-3 Days277V-480V:75 In StockShips 2-3 Days
- Watts: 600
- Lumens: 84000
- Lumens/Watt: 140
- Replaces: 1500 Watt Metal Halide
- Color Temp: 4000K | 5000K
- CRI: 70+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V
- Surge Protection: 6kV line-line, 10kV line-earth
- Operating Temp: -22°F to 113°F (-30°C to 45°C)
- Rated Life: 176,000 (L70) hours
- Dimmable: 1-10V
- Beam Angle: 60°(std), 10°, 15°, 30°, 45°
- Optics: Polycarbonate Optics and Tempered Glass Lens
- Housing: Powder Coated Aluminum
- Fixture Color: Gray
- Mount: Slip Fitter | Trunnion
- EPA Rating: 2.3
- Dimensions: 13.19 in L x 6.42 in W x 22.13 in H
- Cord Length: 5 Feet
- Weight: 38 lbs
Starting At$686.09 - SKU:MLLG-LED-HPSL-400-57-60-[F] | Web ID:2092100V-277V Standard Finish:404 In StockShips 2-3 Days277V-480V Standard Finish:Built to Order 8 Weeks100V-277V Marine Grade:Built to Order 8 Weeks277V-480V Marine Grade:Built to Order 8 Weeks
- Watts: 400
- Lumens: 60000
- Lumens/Watt: 150
- Replaces: 1000 Watt Metal Halide
- Color Temp: 3000K | 4000K | 5700K
- CRI: 80+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V
- Surge Protection: 10KV line-line, 20KV line-earth
- Operating Temp: -22°F to 122°F (-30°C to 50°C)
- Rated Life: 200,000 (L70) hours
- Dimmable: 0-10V
- Beam Angle: 60°(std), 10°, 30°, 45°, T3
- Optics: Polycarbonate Lens
- Housing: Powder Coated Aluminum
- Fixture Color: Black
- Mount: Trunnion
- EPA Rating: 1.35
- Dimensions: 18.8 in W in X 11.2 in H X 7.3 in D
- Cord Length: 4 Feet
- Weight: Fixture body 14 lbs Driver Box 8 lbs
Starting At$551.76 - SKU:MLLG-LED-HPSL-600-57-60-[F] | Web ID:2093100V-277V Standard Finish:43 In StockShips 2-3 Days277V-480V Standard Finish:Built to Order 8 Weeks100V-277V Marine Grade:Built to Order 8 Weeks277V-480V Marine Grade:Built to Order 8 Weeks
- Watts: 600
- Lumens: 90000
- Lumens/Watt: 150
- Replaces: 1500 Watt Metal Halide
- Color Temp: 3000K | 4000K | 5700K
- CRI: 80+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V
- Surge Protection: 10KV line-line, 20KV line-earth
- Operating Temp: -22°F to 122°F (-30°C to 50°C)
- Rated Life: 200,000 (L70) hours
- Dimmable: 0-10V
- Beam Angle: 60°(std), 10°, 30°, 45°, T3
- Optics: Polycarbonate Lens
- Housing: Powder Coated Aluminum
- Fixture Color: Black
- Mount: Trunnion
- EPA Rating: 1.35
- Dimensions: 18.8 in W in X 11.2 in H X 7.3 in D
- Cord Length: 4 Feet
- Weight: Fixture body 17.2 lbs Driver Box 10.4 lbs
Starting At$697.84 - SKU:MLLG-LED-HPSL-800-57-60 | Web ID:2009Built to Order 8 Weeks
- Watts: 800
- Lumens: 120000
- Lumens/Watt: 150
- Replaces: 1500 Watt Metal Halide
- Color Temp: 3000K | 4000K | 5700K
- CRI: 80+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V Optional
- Surge Protection: 10KV line-line, 20KV line-earth
- Operating Temp: -22°F to 122°F (-30°C to 50°C)
- Rated Life: 200,000 (L70) hours
- Dimmable: 0-10V
- Beam Angle: 60°(std), 10°, 30°, 45°, T3
- Optics: Polycarbonate Lens
- Housing: Powder Coated Aluminum
- Fixture Color: Black
- Mount: Trunnion
- EPA Rating: 1.92
- Dimensions: 20 X 17 X 9.2 in
- Weight: Fixture: 30.2 lbs Driver Box: 12 lbs
Starting At$1,327.18 - SKU:MLLG-LED-HPSL-1200-57-60 | Web ID:2011Built to Order 8 Weeks
- Watts: 1200
- Lumens: 180000
- Lumens/Watt: 150
- Replaces: 2000 Watt Metal Halide
- Color Temp: 3000K | 4000K | 5700K
- CRI: 80+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V Optional
- Surge Protection: 10KV line-line, 20KV line-earth
- Operating Temp: -22°F to 122°F (-30°C to 50°C)
- Rated Life: 200,000 (L70) hours
- Dimmable: 0-10V
- Beam Angle: 60°(std), 10°, 30°, 45°, T3
- Optics: Polycarbonate Lens
- Housing: Powder Coated Aluminum
- Fixture Color: Black
- Mount: Trunnion
- EPA Rating: 2.68
- Dimensions: 20 in W in X 22.5 in H X 11.3 in D
- Weight: Fixture body 42 lbs Driver Box 14.5 lbs
Starting At$1,635.42 - SKU:LLS-RSL-600A-50-60-[V]-TR | Web ID:2569100V-277V:Built to Order 6 Weeks200V-480V:Built to Order 6 Weeks
- Watts: 400 | 500 | 600
- Lumens: 68000 | 85000 | 105000
- Lumens/Watt: 170
- Replaces: 1500 Watt Metal Halide
- Color Temp: 5000K
- CRI: 80+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 200V-480V
- Surge Protection: 10KV line-line, 20KV line-earth
- Operating Temp: -22°F to 122°F (-30°C to 50°C)
- Rated Life: 200,000 (L70) hours
- Dimmable: 0-10V
- Beam Angle: 60°(std), 15°, 45°, 30°
- Optics: Polycarbonate Lens
- Housing: Powder Coated Aluminum
- Fixture Color: Gray
- Mount: Trunnion
- Dimensions: 16.77 x 19.29 x 11.46
- Weight: 34 lbs
Starting At$988.26 - SKU:LLS-X-OSL-600-57-[Optic]-[V] | Web ID:2501100V-277V:80 In StockShips 3-5 Days277V-480V:128 In StockShips 3-5 Days
- Watts: 600
- Lumens: 93000
- Lumens/Watt: 155
- Replaces: 1500 Watt Metal Halide
- Color Temp: 5700K
- CRI: 70+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V
- Surge Protection: 20kV
- Operating Temp: -40°F to 122°F (-40°C to 50°C)
- Rated Life: 170,000 (L70) hours
- Dimmable: 0-10V
- Beam Angle: 600W: 30°(std) | 800W: 20°(std) | 60°(opt)
- Optics: Polycarbonate Optics
- Housing: Powder Coated Aluminum
- Fixture Color: Black
- Mount: Trunnion
- EPA Rating: 2.5
- Dimensions: 25.6 X 24.4 X 18.9 in
- Cord Length: 3 Feet
- Weight: 60 lbs
Starting At$826.92 - SKU:LLS-X-OSL-800-57-[Optic]-[V] | Web ID:2502100V-277V:92 In StockShips 3-5 Days277V-480V:65 In StockShips 3-5 Days
- Watts: 800
- Lumens: 124000
- Lumens/Watt: 155
- Replaces: 1500 Watt Metal Halide
- Color Temp: 5700K
- CRI: 70+
- IP Rating: IP66
- IK Rating: IK08
- Voltage: 100V-277V | 277V-480V
- Surge Protection: 20kV
- Operating Temp: -40°F to +122°F
- Rated Life: 170,000 (L70) hours
- Dimmable: 0-10V
- Beam Angle (Opt): 20° | 30° | 60°
- Optics: Polycarbonate Optics
- Housing: Powder Coated Aluminum
- Fixture Color: Black
- Mount: Trunnion
- EPA Rating: 2.5
- Dimensions: 25.6 X 24.4 X 18.9 in
- Cord Length: 3 Feet
- Weight: 60 lbs
Starting At$1,017.31
What are LED Football Field Lights?
Football field lighting consists of specialized stadium light fixtures engineered to illuminate large playing surfaces with precision and power. Most installations position fixtures at 70-foot heights, though professional stadiums often require mounting at 250 feet to achieve optimal coverage. Modern LED stadium lights deliver superior brightness and superior light quality compared to traditional lights.
Based on our 17 years of experience, we recommend 400-watt or 600-watt LED sports lights for most football field applications. These high-power fixtures easily outperform metal halide lights while delivering up to 180,000 lumens from our most powerful units. The integrated drivers automatically adjust to your building's electrical supply, handling 100-277V or 277-480V input ranges without additional equipment. For optimal player visibility and broadcast quality, 5000K color temperature provides the ideal white light, though 4000K works well when a slightly warmer appearance is preferred.
Looking for poles? We offer football stadium lights poles and high mast poles as well.

St. Francis Borgia Football Field in Washington, Missouri, Lit Up with our 600 Watt IMF LED sports lights
What are the Benefits of an LED Football Field Lighting System?
| Reduced Energy Consumption | Most facilities experience a 60% or more reduction in utility costs after switching from metal halide. Savings appear immediately on the very first monthly bill. |
| Consistent Lighting | Precision optics eliminate dark spots and bright patches common with older systems. Each fixture delivers even, uniform field illumination. |
| Long Life | Quality LED fixtures operate for 100,000+ hours-over 20 years of typical use- compared to only 2–3 years for metal halide bulbs. |
| Light Quality | High-quality illumination with CRI ratings above 70 reveals true colors on the field. Players track the ball better and TV broadcasts appear sharper. |
| Optic Options | Narrow to wide beam angles allow precise control. Proper optics place light exactly where needed while reducing unwanted spill into surrounding areas. |
| Reduced Glare | Optional side shields reduce glare and improve overall field visibility. |
| Lower Maintenance Costs | No bulb changes or ballast failures. LEDs eliminate the ongoing maintenance headaches of older systems. |
| Instant On | LEDs reach full brightness instantly-no 15–20 minute warm-up period like metal halide systems during games or practice. |
| High Voltage Compatibility | Works with most existing electrical setups. Fully compatible with 120–277V and 277–480V systems without additional transformers. |
| Easy Installation | Most LED sports lights mount directly to existing pole brackets. Standard electrical connections and straightforward aiming ensure fast, predictable installation. |

We have converted hundreds of outdoor sports fields from Metal Halide to LED.
What are the Best Foot Candle Levels for Different Levels of Football Play?
| Collegiate Sports (Televised) | 120–150 foot candles |
| Collegiate Field Lighting | 80–120 foot candles |
| Large High School Lighting | 50–70 foot candles |
| Small High School Lighting | 30–50 foot candles |
| Middle School Lighting | 30–50 foot candles |
| Recreational Football | 10–30 foot candles |
| Practice Fields | 10–20 foot candles |

We converted this sports field in Texas over to LED with our 400 Watt LED Area Flood Light | 56000 Lumens sports lights.
How to Select the Proper LED Football Field Lighting Solution
| Choosing the Right Lighting System | Choosing the right lighting system requires balancing safety, performance, and budget considerations. Our sports field lighting and pole systems deliver comprehensive coverage while maintaining efficiency and player safety. Here are the several factors we evaluate for every project. |
| Lighting Level Requirements | Competitive level determines illumination standards for your field. We analyze your specific requirements and create a free custom lighting plan showing exactly where fixtures should be positioned and which wattages will achieve your target foot candle levels. |
| Existing Pole Considerations | Current pole locations significantly impact your lighting design options. Most of our customers can utilize existing poles, though some projects benefit from additional or replacement poles to optimize coverage. Request a free pole evaluation and quote here. |
| Fixture Mounting Height | Proper mounting height prevents glare and light spill while ensuring adequate illumination for players and spectators. Without existing poles, we typically recommend specific heights based on field dimensions and competition level requirements, then specify appropriate pole solutions. |
| Existing Lighting Setup | Current fixture positioning, mounting methods, fixture quantities per pole, and weight capacity all influence your upgrade options. We design adaptive solutions that maximize your existing infrastructure, reducing installation complexity and overall project costs. |
| Comprehensive Approach | Our comprehensive approach to stadium lights helps facility managers achieve optimal visibility and safety while minimizing long-term operational expenses. |

Need Help? Talk to an LED Football Field Expert.
Selecting the right fixtures and configuration requires specialized knowledge of sports lighting standards and field requirements. Our sales engineers bring extensive expertise in football stadium illumination systems. Share your project details with us, and we'll recommend optimal fixture selections and layouts for your specific application. We provide free lighting plans to guarantee proper illumination levels and uniform light distribution across your entire field.
Safety and Performance Certifications
All our fixtures carry essential certifications, including DLC Premium, UL Listed, and ETL Listed approvals. These certifications ensure safety, performance, and energy efficiency while qualifying your project for utility rebates and tax incentives. DLC Premium certification guarantees the highest efficiency standards and maximum rebate eligibility.
5-Year Warranty and Warranty Support
All our lights come with at least a 5-year warranty, and all warranty support is based in the USA. We take customer support seriously, and helping you with a warranty claim is important to us. Our experienced support team understands the importance of keeping your lighting operational and will work quickly to resolve any warranty issues.
Your LED Football Field Investment Backed by Real Results
Our team delivers precise energy savings calculations for your specific sports facilities before you purchase. We provide detailed ROI analysis comparing your current electricity bills against projected LED costs using your utility rates and usage patterns. With over 1,000 successful municipal field conversions completed since 2007, our data shows most facilities recover their initial investment within 2-3 years through reduced electricity and maintenance expenses. Our DLC Premium fixtures qualify for maximum utility rebates, often covering 30-50% of fixture costs immediately. Our product specialists bring specialized knowledge of Illuminating Engineering Society lighting standards and NCAA requirements, ensuring your project meets exact specifications for competition play while maximizing long-term savings.
Common Mistakes and How to Avoid Them
Most football field lighting failures happen during the design phase when people skip the fundamentals. I've seen too many installations that looked good on paper but failed in practice because someone cut corners or made bad assumptions about existing infrastructure.
- Using residential-grade fixtures for stadium applications. High-power sports lighting requires fixtures rated for continuous duty at full load, not general flood lights.
- Mounting multiple 600-watt fixtures on poles without checking structural capacity. Get an engineer to verify load ratings before you hang heavy LED arrays.
- Installing fixtures with wrong beam spreads that create hot spots and shadows. Match your optics to pole spacing or you'll have uneven coverage across the field.
- Ignoring spill light ordinances and neighbor complaints. Use proper shields and cutoff angles to keep light on the field where it belongs.
- Skipping voltage verification and ordering incompatible drivers. Check your actual supply voltage at the pole before specifying 277V or 480V fixtures.
- Relying on fixture count estimates instead of proper photometric calculations. Every field layout is different and requires actual modeling to hit target foot candle levels.
- Forgetting about maintenance access when positioning fixtures. Mount everything so you can actually reach it with standard lift equipment.
- Connecting high-power LED fixtures to existing metal halide circuits without upgrading wire size. LEDs draw different current profiles that can overload undersized conductors.
High Power LED Football Field Lighting Frequently Asked Questions
How Much Energy Do LED Football Field Lights Save Compared to Metal Halide?
LED football field lights typically reduce electricity costs by 60 percent or more compared to metal halide systems. A 400-watt LED fixture delivers high lumen output equivalent to a 1,000-watt metal halide while consuming 60% less power. Most facilities see the energy savings reflected immediately on their first monthly utility bill after conversion.
What Foot Candle Levels Do Different Football Competition Levels Require?
Collegiate televised games require 120-150 foot candles, while standard collegiate fields need 80-120 foot candles. Large high schools typically require 50-70 foot candles, smaller high schools need 30-50 foot candles, and recreational or practice fields operate effectively with 10-30 foot candles. These standards ensure proper visibility for players and spectators while meeting safety requirements.
How Long Do LED Football Field Lights Last?
Quality LED football field lights operate for 100,000+ hours without replacement, which equals over 20 years of typical use. This dramatically outperforms metal halide bulbs that require replacement every 2-3 years. The extended lifespan eliminates ongoing maintenance costs and reduces the need for expensive lift equipment to access high-mounted fixtures.
What Wattage LED Fixtures Work Best for Football Fields?
We recommend 400-watt or 600-watt LED sports lights for most football field applications based on our experience with over 1,000 successful conversions. Our most powerful units deliver up to 180,000 lumens and easily outperform traditional metal halide systems. The integrated drivers handle 100-277V or 277-480V input ranges without additional transformers.
Can LED Football Field Lights Use Existing Poles and Electrical?
Most LED sports lights mount directly to existing pole brackets using standard electrical connections. The fixtures are compatible with both 120-277V and 277-480V systems without requiring additional transformers. We evaluate existing pole locations, weight capacity, and mounting hardware to design adaptive solutions that maximize current infrastructure while reducing installation costs.
What Color Temperature Works Best for Football Field Lighting?
5000K color temperature provides ideal white light for optimal player visibility and broadcast quality on football fields. This temperature delivers high CRI ratings above 80 that reveal true colors and help players track the ball effectively. 4000K works well when facilities prefer a slightly warmer light appearance while maintaining good visibility.
Do LED Football Field Lights Eliminate Warm-Up Time?
LED fixtures provide full brightness immediately when switched on, unlike metal halide systems that require 15-20 minutes to reach full output. This instant-on capability proves essential for games, practice sessions, and emergency lighting needs. Players and officials can begin activities immediately without waiting for lights to warm up.
Why Choose LED Lighting Supply for Football Field Projects?
We bring over 15 years of commercial and industrial lighting expertise with 25,000+ completed projects to every football field conversion. Our consultative approach includes free custom lighting plans and precise energy savings calculations using your specific utility rates and usage patterns. We provide comprehensive ROI analysis and help secure utility rebates that often cover 30-50% of fixture costs, with most facilities recovering their investment within 2-3 years.
What Certifications Should Football Field LED Lights Have?
All quality football field LED fixtures should carry DLC Premium, UL Listed, and ETL Listed certifications. DLC Premium certification guarantees the highest efficiency standards and maximum utility rebate eligibility. These certifications ensure safety, performance, and energy efficiency while qualifying projects for tax incentives and utility programs.
How High Should Football Field Light Poles Be?
Most football field installations position fixtures at 70-foot heights for optimal coverage and glare control. Professional stadiums often require mounting at 250 feet to achieve proper illumination levels. The mounting height depends on field dimensions, competition level requirements, and existing infrastructure, with proper height preventing glare while ensuring adequate illumination for players and spectators.
What Maintenance Costs Do LED Football Field Lights Eliminate?
LED fixtures eliminate bulb replacement costs, ballast failures, and frequent maintenance visits that drain facility budgets year after year. Traditional metal halide systems require expensive lift equipment and labor for bulb changes every 2-3 years, while LEDs operate maintenance-free for 100,000+ hours. This eliminates both material costs and the labor expenses associated with high-mounted fixture servicing.








![Mllg Ag Led Imf 600 5 [optic] Tr [v]](jpg/mllg-ag-led-imf-600-5-optic-tr-v-1-800x800.jpg)