Trust Pilot Reviews
Menu
Search Icon
LED Lighting Supply Certification Stamp

LED Lights for Shooting Ranges

By LED Lighting Supply

  • 50-75% energy savings with immediate monthly cost reductions
  • DLC Premium and UL Listed certifications ensure safety compliance
  • 5-year USA-based warranty with experienced technical support team
  • IP65 weatherproof ratings with IK08 impact resistance durability
Led Flood Lights
DLC Certification UL Certification ETL Certification 5 Year Warranty
Our commitment to quality Our products are held to the highest standards for performance & reliability LED Lighting Supply Certification Stamp
Get Your Custom Lighting Plan With Product Recommendations
  • Blue Check Mark Professional Layout Designed for Target Illumination & Shooter Safety Requirements
  • Blue Check Mark Precise Foot Candle Calculations & Glare-Free Positioning for Optimal Visibility Standards
  • Blue Check Mark Reduce Energy Costs & Maintenance While Meeting Range Safety Regulations
Lighting Plan Image Lighting Plan Image Heat Map
Request Your Free Lighting Plan

LED shooting range lights provide specialized illumination designed for firearms training facilities, delivering precise target visibility while ensuring shooter safety and comfort. These energy-efficient fixtures eliminate the warm-up delays and maintenance issues of traditional metal halide systems, offering instant-on performance with 50-75% energy savings for shooting ranges and trap fields. LED Lighting Supply shooting range lights serve both indoor training facilities and outdoor trap shooting venues where consistent, high-quality illumination is critical for accuracy and safety. Indoor ranges typically require 50-100 foot candles at firing lines and target areas, while outdoor facilities need 20-50 foot candles for general areas and up to 100 foot candles in target zones. These fixtures mount strategically to avoid bullet damage while providing uniform coverage across firing lines and downrange target areas. Our fixtures deliver superior performance compared to metal halide systems through advanced LED technology that maintains 90% of initial brightness after 50,000 hours. The instant-on capability eliminates 15-minute warm-up delays that interrupt training schedules, while flicker-free output reduces eye fatigue during extended sessions. Integrated glare control and optical systems direct light precisely where needed, improving target definition without creating distracting spill light that can affect shooter concentration. All fixtures carry DLC Premium, UL Listed, and ETL Listed certifications ensuring safety compliance while qualifying facilities for utility rebates and energy incentives.
View More
Find Faster - Try Filters!

Selected Filters

Watts

Lumens

Voltage

Color Temperature

Metal Halide Equivalent

Certifications

Features

Fixture Color

IP Rating

IK Rating

Dimming

Mounting Options

Indoor / Outdoor

Availability

SHOW FILTERS

Selected Filters

Watts

Lumens

Voltage

Mounting Options

Color Temperature

Metal Halide Equivalent

Certifications

Features

Fixture Color

IP Rating

IK Rating

Dimming

Indoor / Outdoor

Availability

What are LED Shooting Range Lights?

LED Shooting Range Lights deliver specialized illumination engineered specifically for firearms training facilities and outdoor trap fields. After 17 years designing commercial lighting systems, we understand the unique challenges these environments present. The lighting must provide clear target visibility downrange while maintaining shooter safety and comfort.

Our fixtures are strategically positioned to avoid bullet damage while delivering consistent illumination across both firing lines and target zones. We serve indoor facilities requiring precision lighting control and outdoor ranges where weather resistance becomes critical.

Mllg Ag Led Imf 400 5 60 Tr Hv

What is LED Trap Field Lighting?

Trap field lighting enables evening clay pigeon shooting by illuminating the flight paths where targets travel. Fixtures mount on tall poles positioned behind shooting stations to avoid interference while providing broad coverage of the target zone. Most of our trap field customers choose 400-750 watt fixtures with 30-60 degree beam patterns for optimal clay visibility.

Skeet fields benefit from identical lighting approaches, though the flight patterns may require slightly different pole positioning. We typically recommend creating a comprehensive lighting layout to ensure proper coverage across the entire target area and eliminate dark spots that could affect shooter performance.

What are the Benefits of Using LED Lighting Supply Shooting Range Lights?

Modern LED systems dramatically outperform traditional metal halide installations across multiple performance categories.

Energy Efficiency Facilities switching to LED technology reduce electricity consumption by 50-75 percent compared to metal halide systems. Range operators see immediate monthly savings, especially important for facilities with extended operating hours.
Powerful Lighting Our fixtures generate high-output lumens that equal or surpass metal halide brightness levels. Direct one-for-one replacement becomes possible without compromising illumination quality or target visibility.
Lower Maintenance Costs LED technology eliminates frequent bulb and ballast replacements that plague HID systems. Maintenance teams spend less time on fixture service and more time on facility operations.
Slow Lumen Depreciation Premium LED chips maintain 90 percent of initial brightness after 50,000 operating hours. Traditional metal halide lamps lose substantial output within months of installation.
Instant On Full brightness activates immediately when power switches on. Range operators avoid the 15-minute warm-up delays that interrupt training schedules with HID lighting.
High-Quality Lighting Consistent, flicker-free output with superior color rendering ensures accurate target identification under all conditions. Shooters experience less eye fatigue during extended training sessions.
Greater Experience Enhanced target definition and reduced visual strain improve shooter accuracy while creating more comfortable training environments. Customer satisfaction increases measurably.
Glare Control Advanced optical systems and integrated shields direct light precisely where needed while minimizing spill light and distracting glare that can affect shooter concentration.

Mllg Ag Led Imf 400 5 60 Tr Hv

What are the Recommended Foot Candles for Shooting Ranges?

Indoors

Firing Line and Shooting Stalls 50-100 fc
Target Area 50-100 fc
Instruction Areas 30-50 fc
Ammunition and Equipment Handling 50-75 fc

Outdoors

Shooting Range (General Area) 20-50 fc
Shooting Range (Target Area) 40-100 fc
Trap Shooting (Shooting Stations) 20-40 fc
Trap Shooting (Target Area) 40-100 fc

Safety and Performance Certifications

All our fixtures carry essential certifications, including DLC Premium, UL Listed, and ETL Listed approvals. These certifications ensure safety, performance, and energy efficiency while qualifying your project for utility rebates and tax incentives. DLC Premium certification guarantees the highest efficiency standards and maximum rebate eligibility.

UL Listed Certification for Electrical Safety and Performance ETL Listed Certification for Product Safety Compliance DLC Qualified for High Energy Efficiency and Utility Rebates NSF Certified for Food-Safe and Sanitary Lighting Applications This LED Fixture is Dimmable 1-10V IP65 Rated - Dust Tight and Water Resistant Lighting Fixture IK08 Impact Rated - Durable Fixture with High Resistance to Mechanical Impact Built-in Motion Sensor - Automatic Lighting Control for Energy Efficiency and Safety 5-Year Warranty - Backed Assurance of Product Quality and Long-Term Reliability

5 Year Warranty and Warranty Support

All our lights come with at least a 5-year warranty, and all warranty support is based in the USA. We take customer support seriously, and helping you with a warranty claim is important to us. Our experienced support team understands the importance of keeping your lighting operational and will work quickly to resolve any warranty issues.

Expert Support for Your Shooting Range Lighting Project

Our lighting specialists provide complimentary energy savings calculations showing your exact cost reductions and payback timeframes before you purchase. These detailed analyses compare your current energy costs against LED performance data to demonstrate the real monthly savings your facility will achieve. Our product specialists average over 8 years of commercial LED experience and understand the specific fixture requirements for different range configurations, target distances, and safety considerations. We provide custom lighting layouts that optimize fixture placement for your exact facility dimensions while ensuring proper foot candle levels across all zones. This technical expertise helps you avoid costly lighting mistakes and ensures your investment delivers maximum performance and energy savings from day one.

Common Mistakes and How to Avoid Them

We see the same basic errors on range lighting jobs that end up costing facilities real money. Most of these come down to not understanding how bullets and light paths interact in these environments.

  • Mounting fixtures where they can take bullet hits or fragments. Keep everything behind the firing line or use armored housings rated for the calibers being used.
  • Creating glare that washes out iron sights and scope reticles. Use cutoff shields and position fixtures to light targets without backlighting the shooter's view.
  • Underestimating the wattage needed for trap and skeet fields. Those clay birds move fast and you need serious lumens to track them properly.
  • Using indoor-rated fixtures on outdoor ranges. Moisture and temperature swings will kill non-weatherproof equipment within months.
  • Not checking actual foot candle levels after installation. Your light meter should confirm you're meeting NRA standards for the disciplines being shot.
  • Installing fixtures too low or too high for the range layout. Wrong mounting height creates shadows or hot spots that affect shooter performance.
  • Forgetting about emergency shutoff switches that range officers can reach quickly. Some jurisdictions require this for safety compliance.
  • Skipping surge protection on outdoor installations. Lightning strikes and power fluctuations are expensive lessons in these applications.

LED Lights for Shooting Ranges Frequently Asked Questions

What Type of LED Fixtures Work Best for Indoor Shooting Ranges?

High-bay LED fixtures with Type 5 optics provide optimal coverage for most indoor ranges. We recommend fixtures that deliver 50-100 foot candles at the firing line and target areas while maintaining 70+ CRI for accurate target identification. Fixtures should include glare shields to prevent direct light from affecting shooter vision.

How Much Can Shooting Ranges Save by Converting to LED Lighting?

LED systems reduce energy consumption by 50-75% compared to metal halide fixtures. A typical indoor range operating 12 hours daily can save $3,000-8,000 annually in electricity costs alone. Maintenance savings add another $1,500-3,000 per year by eliminating frequent bulb and ballast replacements that plague HID systems.

What Wattage LED Fixtures Are Required for Trap Field Lighting?

Most trap fields require 400-750 watt LED fixtures with 30-60 degree beam patterns mounted on poles behind shooting stations. The exact wattage depends on pole height, target distance, and desired foot candle levels. We typically design systems to deliver 40-100 foot candles in the target flight zone for optimal clay visibility.

How Do You Prevent Bullet Damage to LED Fixtures in Shooting Ranges?

Strategic fixture placement positions lights outside bullet trajectories while maintaining proper illumination angles. Indoor ranges mount fixtures above the firing line and target areas using bullet-resistant housings when necessary. Outdoor ranges utilize tall poles and careful positioning to keep fixtures in safe zones while providing adequate coverage.

What Certifications Should Shooting Range LED Fixtures Have?

Quality fixtures must carry UL Listed and DLC Premium certifications for safety and energy efficiency. These certifications ensure reliable performance and qualify your project for utility rebates. IP65 ratings provide essential protection against dust and moisture, while IK08 impact resistance handles the vibrations common in shooting environments.

Why Choose LED Lighting Supply for Your Shooting Range Project?

We provide comprehensive lighting analysis including custom layouts and energy savings calculations before you purchase anything. Our specialists leverage experience from 25,000+ commercial projects to design optimal fixture placement for your specific range configuration. We handle everything from initial consultation through installation support, ensuring your lighting investment delivers maximum performance and ROI.

How Long Do LED Shooting Range Lights Last Compared to Metal Halide?

Quality LED fixtures maintain 90% of initial brightness after 50,000 operating hours compared to metal halide lamps that degrade significantly within months. LED systems typically operate 15-20 years before requiring replacement, while metal halide lamps need replacement every 6-12 months. This longevity eliminates the frequent maintenance interruptions that disrupt range operations.

What Foot Candle Levels Are Required for Different Shooting Range Areas?

Indoor ranges need 50-100 foot candles at firing lines and target areas, with 30-50 foot candles in instruction zones. Outdoor ranges require 20-50 foot candles in general areas and 40-100 foot candles in target zones. Trap shooting stations need 20-40 foot candles with 40-100 foot candles where clay targets fly.

Do LED Shooting Range Lights Eliminate the Warm-Up Time of Metal Halide Systems?

LED fixtures provide full brightness instantly when switched on, eliminating the 15-minute warm-up delays that interrupt training schedules with HID lighting. This instant-on capability allows ranges to operate more efficiently and respond immediately to customer needs. Facilities can also implement motion sensors and dimming controls to further reduce energy consumption without operational delays.

What Technical Support Does LED Lighting Supply Provide for Range Projects?

Our lighting specialists create detailed photometric layouts showing exact fixture placement and foot candle calculations for your facility dimensions. We provide complimentary energy analysis comparing your current costs against LED performance to demonstrate real monthly savings. Our team averages over 8 years of commercial LED experience and understands the specific requirements for different range configurations, target distances, and safety considerations.

How Do LED Shooting Range Lights Handle Vibration from Gunfire?

Professional LED fixtures use solid-state technology with no fragile filaments or glass components that break from vibration. Quality fixtures include IK08 impact ratings and robust mounting hardware designed for industrial environments. The absence of ballasts eliminates another common failure point that affects HID systems in high-vibration applications.

Can LED Shooting Range Lights Be Dimmed for Different Training Scenarios?

Most commercial LED fixtures include 0-10V dimming capability allowing ranges to adjust light levels for different training requirements. Dimming extends fixture life, reduces energy consumption during low-activity periods, and provides flexibility for specialized training scenarios. Advanced control systems can automate dimming schedules and integrate with occupancy sensors for maximum efficiency.


//