What is a Foot Candle?

A foot-candle measures light intensity, equivalent to one lumen of light per square foot. It measures the light that reaches a surface, while lumens measure the quantity of light produced by a fixture.

Footcandles, equivalent to approximately 10.764 lux, are vital for measuring light intensity in commercial, industrial, and sports lighting. They define the required lighting levels for various environments, ensuring safety and functionality.

As set by organizations like OSHA, compliance with footcandle and lighting standards is essential for safe and adequately lit workplaces. In sports lighting, footcandles ensure optimal visibility for players and spectators.

The Illuminating Engineering Society (IES) defines illuminance standards that help establish appropriate foot-candle levels for different applications. These standards work in conjunction with OSHA’s workplace lighting requirements to ensure both safety and productivity in various environments.

Best Sellers: LED High Bays

Recommended Foot Candles for Commercial Projects

Aircraft Hangar With Led Ufo Hbho 240 2

Recommended Foot Candles for Airplane Hangars

Task / AreaRecommended Foot Candles
General Work / Storage30 fc
Aircraft Maintenance (some detailed tasks)30–50 fc
Aircraft Maintenance (fine detailed tasks)70–100 fc
Drilling, Riveting, Screw Fastening75 fc
Final Assembly100 fc
Inspection50–200 fc
Welding50 fc
Get your free Aircraft Hangar Lighting Plan

Recommended Foot Candles for Banks

Task / AreaRecommended Foot Candles
ATM10-40 fc
Lobby10-50 fc
Writing Areas20-70 fc
Teller Stations, Posting, and Keypunch50-150 fc

Recommended Foot Candles for Billboards

Task / AreaRecommended Foot Candles
Level 1 Billboard20 fc
Level 2 Billboard50-60 fc
Level 3 Billboard100 fc

* Note: Average / Minimum Foot Candle Ratio should be < 4.0. A better target of 2.0 would mean the billboard is uniformly lit.

Recommended Foot Candles for Convention Centers & Exhibition Halls

Task / AreaRecommended Foot Candles
Main Convention Area30-90 fc
Smaller Meeting Rooms30-50 fc
Stairways5 fc
Washrooms and Restrooms5 fc

Recommended Foot Candles for Commercial Kitchens

Task / AreaRecommended Foot Candles
General Kitchen Area50-75 fc
Specialized Work Stations50-150 fc
Cooking Stations and Grills100-200 fc
Storage and Refrigeration20-50 fc

Get your Free Commercial Kitchen Lighting Plan

Recommended Foot Candles for Data Centers

Task / AreaRecommended Foot Candles
Server Rooms30-50 fc
Repair Areas50-75 fc
Storage Areas20-30 fc
Hallways and Corridors20-30 fc

Get your Free Data Center Lighting Plan

Recommended Foot Candles for Food Service Facilities

Task / AreaRecommended Foot Candles
Cashier Stand20-50 fc
Cleaning Areas10-20 fc
Dining Areas5-20 fc
Food Courts30 fc
Food Displays30-100 fc
Kitchen, Food Prep50-100 fc

Recommended Foot Candles For Garage / Workshops

Task / AreaRecommended Foot Candles
Hobby Work30 fc
Work with limited detailed tasks30-50 fc
Work with fine-detailed tasks70 fc

Get your Free Garage / Workshop Lighting Plan

Recommended Foot Candles for Hospitals – Medical Facilities

Task / AreaRecommended Foot Candles
Hallways5-30 fc
Patient Waiting Areas10 fc
Nurse Stations30 fc
Hospital Lobby Areas5 fc
Medical Record Areas50 fc
Stair Areas10 fc
Rooms10-30 fc
Emergency Rooms50-100 fc
General Nursing Station30
Operating Rooms100-200

Recommended Foot Candles for Hotels

Task / AreaRecommended Foot Candles
Bathrooms20-50 fc
Bedrooms – Reading20-50 fc
Corridors, Elevators, Stairs10-20 fc
Front Desk50-100 fc
Linen Room – General10-20 fc
Linen Room – Sewing100-200 fc
Lobby, General10-20 fc
Reading and Working Areas20-50 fc

Recommended Foot Candles for Laundries

Task / AreaRecommended Foot Candles
Washing20-50 fc
Ironing20-100 fc

Recommended Foot Candles for Libraries

Task / AreaRecommended Foot Candles
Ordinary Reading, Stacks20-50 fc
Book Repair and Binding20-50 fc

Study and Note Taking, Cataloging, Card Files, Checkout Desk

20-100 fc

Recommended Foot Candles for Machine Shops

Task / AreaRecommended Foot Candles
Rough Bench20-50 fc
Medium Bench, Rough Grinding, Buffing50-100 fc
Fine Bench200-500 fc

Recommended Foot Candles For Offices

Task / AreaRecommended Foot Candles
Open Cubicle Space30 fc
Private50 fc
Reception Areas10 fc
Conference Rooms30 fc
Video Conferences50 fc

Get your Free Commercial Office Lighting Plan

Recommended Foot Candles for Parking Lots and Parking Garages

Task / AreaRecommended Foot Candles
Entrances5 fc
Parking Garage – Basic1 fc
Parking Garage – Ramps1-2 fc
Parking Lots2-5 fc
Vehicle Storage2-5 fc

Get your free Parking Lot Lighting Plan and Design

Recommended Foot Candles for Retail Stores

Task / AreaRecommended Foot Candles
Circulation Area Stockroom10-30 fc
Department Store20-80 fc
Discount Warehouse, Drug/Convenience25-100 fc
Merchandising, Self-Service200 fc
Shopping Mall30 fc

Recommended Foot Candles for Schools

Task / AreaRecommended Foot Candles
Classrooms30-50 fc
College Lecture Halls50-100 fc
Hallways10 fc
Smaller School Gymnasiums30-50 fc
Larger School Gymnasiums50-100 fc

Recommended Foot Candles for Security Fences

Task / AreaRecommended Foot Candles
High-Security Areas (Prisons – for example)5 fc
Low-Security Areas1-2 fc

Recommended Foot Candles For Warehouses and Manufacturing

Manufacturing

Task / AreaRecommended Foot Candles
Coarse Material Processing10 fc
Medium Material Processing30 fc
Fine Material Processing50 fc
Extra Fine Material Processing50-100 fc
Wrapping, Packaging and Labeling30 fc
Picking Stock30 fc
Simple Assembly15-60 fc
Medium Assembly25-100 fc
Difficult Assembly50-200 fc
Complicated Assembly50-200 fc
Exacting Assembly and Inspection150-600 fc
General Food Processing75 fc

Warehousing

Task / AreaRecommended Foot Candles
Warehousing – Inactive Area5-10 fc
Warehousing – Active – Large Items10-20 fc
Warehousing – Active – Small Items15-60 fc
Warehousing – Active – Medium Items20 fc
Warehousing – Active – Fine Items20-50 fc
Shipping and Receiving Area30 fc
Receiving and Shipping Dock5-20 fc
Receiving and Staging15-60 fc
Maintenance and Shop Areas50 fc
Cold Storage10-30 fc
Open Warehouse10-30 fc
Warehouse with Aisles10-30 fc

The U.S. Department of Energy’s commercial building guidelines emphasize that proper warehouse lighting can reduce energy consumption by up to 50% when upgrading from high pressure sodium or metal halide systems to LED technology, while maintaining the recommended foot-candle levels for safe operations.

Get your Free Warehouse Lighting Plan and Design

Recommended Foot Candles for Woodworking

Task / AreaRecommended Foot Candles
Rough Sawing and Bench Work20-50 fc
Sizing, Planning, Rough Sanding, Medium Quality Machine and Bench Work, Gluing, Veneering, Cooperage20-50 fc
Fine Bench and Machine Work, Fine Sanding, and Finishing50-100 fc
Workshop30-75 fc

Recommended Foot Candles for Pole Barns

Task / AreaRecommended Foot Candles
Storage or light-duty occasional work and maintenance20-30 fc
Pole barn used as workshop / mechanical area30-50 fc
Fine Detail Work50-75 fc

Get your Free Pole Barn Lighting Plan and Design

Recommended Foot Candle for Industrial Projects

Class 1 Div 2 Explosion Proof Lights

Class 1 Div 1 Explosion Proof Lights

High Temp Lights

power plant LED lighting

Industrial environments often require specialized lighting that meets both safety and classification requirements. The National Fire Protection Association’s NFPA 70 (National Electrical Code) provides detailed requirements for hazardous location lighting installations. Additionally, fixtures used in these environments must be tested and certified by UL (Underwriters Laboratories) to ensure they meet the necessary safety standards for their specific classification.

Recommended Foot Candles for Automobile Manufacturing and Sales

Task / AreaRecommended Foot Candles
Final Assembly, Finishing, Inspection200 fc
Body and Chassis Assembly100 fc
Body Parts Manufacturing100 fc
Frame Assembly50 fc
Showroom25-100 fc
Service Area25-100 fc
Sales Lot (Exterior) – Lighting Zone 3 (urban)10-40 fc
Sales Lot (Exterior) – Lighting Zone 2 (suburban)10-30 fc

Recommended Foot Candles for Clothing Manufacturers

Task / AreaRecommended Foot Candles
Receiving, Storage, Shipping, Winding, Measuring20-50 fc
Pattern Making, Trimming50-100 fc
Shops, Marking50-200 fc
Cutting, Pressing100-500 fc
Sewing, Inspection200-500 fc

Recommended Foot Candles for Distilleries

Task / AreaRecommended Foot Candles
Malting20-30 fc
Barrel Filling20-30 fc
Sorting, Washing, Packing30-40 fc
Filtering50 fc
Bottling50 fc
Inspection100 fc

Recommended Foot Candles for Electrical Equipment Manufacturing

Task / AreaRecommended Foot Candles
Impregnating20-50 fc
Insulating, Coil Winding, Testing50-100 fc

Recommended Foot Candles for Foundries

Task / AreaRecommended Foot Candles
Annealing Furnaces20-50 fc
Cleaning20-50 fc
Core Making50-200 fc
Inspection – Fine100-500 fc
Inspection – Medium50-100 fc
Molding50-200 fc
Pouring, Sorting50-100 fc

Recommended Foot Candles for Iron & Steel Manufacturing

Task / AreaRecommended Foot Candles
Stock, Hot Top, Checker Cellar, Calcining10-30 fc
Building, Slag Pits, Stripping Yard20 fc
Control Platforms, Repairs, Mixer Building30 fc
Rolling Mills30-50 fc
Shearing50 fc
Tin Plate50 fc
Motor Room, Machine Room30 fc
Inspection100 fc

Recommended Foot Candles for Paint Shops

Task / AreaRecommended Foot Candles
Spraying, Hand Art, Stencil20-50 fc
Fine Hand Painting and Finishing50-100 fc

Recommended Foot Candles for Paper Manufacturing

Task / AreaRecommended Foot Candles
Beaters, Grinding20-50 fc
Finishing, Cutting50-100 fc
Hand Counting50-100 fc
Paper Machine Reel, Inspection100-200 fc
Rewinder100-200 fc

Recommended Foot Candles for Printing

Task / AreaRecommended Foot Candles
Photo Engraving, Etching, Blocking20-50 fc
Color Inspecting100-200 fc
Presses50-100 fc
Proofreading100-200 fc
Composing Room50-100 fc

Recommended Foot Candles for Sheet Metal Works

Task / AreaRecommended Foot Candles
General100 fc
Tin Plate Inspection, Galvanized, Scribing100-200 fc

Recommended Foot Candles for Textile Mills

Task / AreaRecommended Foot Candles
Cotton Picking, Carding, Roving, Spinning50 fc
Beaming and Slashing150 fc
Drawing200 fc

Recommended Foot Candles for Water Treatment Plant

Task / AreaRecommended Foot Candles
General Work Areas20-30 fc
Control Rooms50-75 fc
Chemical Handling Areas30-50 fc
Maintenance Areas / Workshops50-100 fc
Labs75-100 fc

Recommended Foot Candles for Sports Projects

Best Selling LED Sport Field Lights


Baseball Softball Fields

Recommended Foot Candles for Baseball and Softball Fields

Task / AreaRecommended Foot Candles
Collegiate (Televised)Infield 100 fc | Outfield 70 fc
CollegiateInfield 70 fc | Outfield 50 fc
High SchoolInfield 50 fc | Outfield 30 fc
Little LeagueInfield 50 fc | Outfield 30 fc
RecreationalInfield 30 fc | Outfield 20 fc

Get Your Free Baseball Field Lighting Design

Get Your Free Softball Field Lighting Design

Recommended Foot Candles for Basketball Courts

Indoors

Task / AreaRecommended Foot Candles
Recreational30-50 fc
High School Level40-70 fc
College and Professional Level70-120 fc

Outdoors

Task / AreaRecommended Foot Candles
Recreational10-30 fc
Competitive Play20-60 fc

Get Your Free Basketball Court Lighting Design

Recommended Foot Candles for Batting Cages

Task / AreaRecommended Foot Candles
Professional Level65-100 fc
Training40-50 fc
Recreation Level20-30 fc

Get Your Free Batting Cage Lighting Design

Recommended Foot Candles for Tennis Courts

Indoor Tennis Courts

Task / AreaRecommended Foot Candles
College / Televised90-120 fc
Competition Level60-90 fc
Club Level40-70 fc
Recreation Level25-40 fc

Outdoor Tennis Courts

Task / AreaRecommended Foot Candles
College / Televised70-100 fc
Competition Level50-80 fc
Club Level30-60 fc
Recreation Level20-35 fc

Get your free Tennis Court Lighting Design

Recommended Foot Candles for Pickleball Courts

Indoor Pickleball Courts

Task / AreaRecommended Foot Candles
Competition Level60-80 fc
Club Level40-60 fc
Recreation Level25-35 fc

Outdoor Pickleball Courts

Task / AreaRecommended Foot Candles
Competition Level50-70 fc
Club Level20-50 fc