Oil Refinery Lighting Design
Get Your Custom Lighting Plan With Product Recommendations
What to Expect When Requesting a Lighting Plan
Our Customers
Frequently Asked Questions
What Goes into Successful Oil Refinery Lighting Design?
An oil refinery lighting design considers existing fixture locations, new installation requirements, and explosion-proof ratings. We evaluate how many lights you need, current lighting types, and required light levels based on industry specifications and safety guidelines. Using CAD drawings, our refinery lighting design provides a visual report of light levels and balanced illumination across all critical areas to ensure optimal safety and operational efficiency.
What are the Benefits of Creating an Oil Refinery Lighting Plan?
A lighting plan eliminates the risks of purchasing fixtures without knowing performance outcomes. We determine exact lumen requirements and beam angles needed for your specific refinery application. Without proper planning, you risk inadequate light levels, unbalanced illumination, and dangerous shadow zones. Our free lighting plans using explosion proof lighting resolve these issues in software before any money is spent.
Class 1 Div 2 Explosion Proof Lights

100 Watt Round Explosion Proof LED Light | Class 1 Div 2
$564.60
Availability:133 in Stock

240 Watt Round Explosion Proof LED Light | Class 1 Div 2
$689.20
Availability: Arriving Soon

300 Watt Round Explosion Proof LED Light | Class 1 Div 2
$924.53
Availability: Arriving Soon

400 Watt Round Explosion Proof LED Light | Class 1 Div 2
$943.40
Availability:5 in Stock

150 Watt Square Explosion Proof LED Light | Class 1 Div 2
$584.91
Availability:76 in Stock
Class 1 Div 1 Explosion Proof Lights

80 Watt Round Explosion Proof LED Light | Class 1 Div 1
$648.15
Availability:227 in Stock

150w Round Explosion Proof Light | C1D1
$911.82
Availability:256 in Stock

150 Watt Square Explosion Proof LED Light | Class 1 Div 1
$963.64
Availability:40 in Stock

60 Watt Explosion Proof Linear LED Light | Class 1 Div 1
$1026.79
Availability:46 in Stock

100 Watt Explosion Proof Linear LED Light | Class 1 Div 1
$1136.36
Availability:160 in Stock
What is the Best Way to Start Designing an Oil Refinery Lighting Plan?
Start with a scaled floor plan or provide exact area dimensions for large open spaces. We need mounting heights and desired foot candle levels for your specific refinery operations. If you’re unsure about required light levels, describe the space usage and we’ll recommend appropriate illumination standards. We’ll create an initial plan and refine it until we achieve your exact lighting requirements.
How Do I Plan the Lighting Layout for an Oil Refinery?
Our lighting plan service handles the complete layout design for you. We need building dimensions, required light levels, current fixture details, and input voltage specifications. Our comprehensive lighting plans calculate the total number of fixtures needed, optimal placement locations, average foot candles throughout the area, and light balance uniformity across the entire space.

How Do You Choose the Right LED Light Fixtures for an Oil Refinery?
Selecting appropriate hazardous location lighting requires expertise in explosion-proof ratings, environmental conditions, and operational requirements. We evaluate your specific refinery environment, including temperature ranges, chemical exposure, and safety classifications. Our team helps you choose fixtures that provide optimal illumination while meeting all safety standards and regulatory compliance requirements.
What Will the Lighting Plan Show Me?
The lighting plan displays a visual foot candle map showing exact illumination levels across your refinery floor. You’ll see light distribution patterns, average-to-minimum ratios for balance calculations, and fixture placement recommendations. The plan identifies potential dark spots or over-lit areas before installation, ensuring uniform coverage throughout all work areas.

How Long Does It Take to Complete an Oil Refinery Lighting Plan?
Most oil refinery lighting plans are completed within 3-5 business days after receiving your floor plans and specifications. Complex multi-area refineries may require 7-10 business days for comprehensive analysis. We provide free revisions to adjust fixture placement, quantities, or light levels based on your feedback until the design meets your exact requirements.
What Information Do You Need to Create My Lighting Plan?
We require scaled floor plans or CAD drawings, mounting heights, current fixture specifications, and desired foot candle levels. Include information about hazardous area classifications, operational schedules, and any existing lighting issues. Providing photos of current conditions and utility voltage specifications helps us create the most accurate lighting design for your refinery.
Can You Design Lighting for Different Hazardous Zones in My Refinery?
Yes, we design lighting solutions for all hazardous location classifications, including Class I Division 1 and 2 areas. Our plans specify appropriate explosion-proof fixtures, vapor-tight housings, and safety-rated components for each zone. We ensure compliance with NEC requirements and industry standards while maintaining optimal illumination levels throughout different operational areas.
Sample Oil Refinery Lighting Plan and HeatMap