Product Description
60 Watt LED Explosion Proof - Class 1 Division 2 light is a compact linear fixture that replaces fluorescent lighting for hazardous locations.
UL Specs
- UL844 Hazardous Locations
- Class 1 Division 2: Group A,B,C,D
- Wet Locations (UL 1598)
Key Features
- Watts: 60
- Lumens: 7800
- Lumens Per Watt: 130
- Replaces: 250 Watt Metal Halide
- Voltage: 100V-277V
- Color Temperature: 5000K
- CRI: 70+
- Dimming: No
- Beam Angles (Std): 120°
- Lifespan: 50,000 (L70) hours
- Mounting: Bracket or Surface or Wall
- Frequency: 50-60Hz
- Power Factor: >.95
- THD: < 10%
Durable Construction
- Housing: Die-Cast Aluminum
- IP Rating: IP66
- Surge Protection: 4kV
- Operating Temperature: -40°F to 131°F
- Certifications: UL | Rebate Eligible
- Warranty: 5 years
Measurements
- Dimensions: 48.4 x 4.9 x 3.5
- Weight: 17 lbs
Notes
Reliable Illumination for Hazardous Environments
Built for environments where safety and performance cannot be compromised, this 60-watt explosion-proof linear LED fixture delivers 7800 lumens of crisp 5000K daylight illumination. Engineered to handle demanding conditions in Class 1 Division 2 and Class 2 Division 2 locations, the compact linear design provides consistent lighting while meeting stringent hazardous location requirements. With its die-cast aluminum housing and IP66 rating, this fixture ensures dependable operation across industrial facilities where moisture, dust, and volatile environments present ongoing challenges.
Replacing Older Lighting Systems
When upgrading from metal halide systems, this LED fixture provides a direct replacement for 250-watt metal halide units while consuming 75% less energy. The 130 lumens per watt efficiency and 50,000-hour lifespan significantly reduce both operating costs and maintenance requirements compared to legacy fixtures.
- Eliminates warm-up time and frequent lamp changes associated with metal halide technology
- Reduces energy consumption from 250 watts to just 60 watts per fixture
- Maintains consistent light output throughout its extended operational life
- Operates reliably in extreme temperatures from -40°F to 131°F
Mounting, Setup & Controls
For most installations, the versatile mounting system accommodates bracket, surface, or wall mounting configurations to match existing infrastructure requirements. The universal 100-277V input voltage simplifies electrical connections across different facility power systems, while the high power factor exceeding 0.95 ensures efficient operation with minimal harmonic distortion below 10%.
Certifications
- UL844 certified for hazardous location applications
- Class 1 Division 2 Groups A, B, C, and D approval
- Class 2 Division 2 rating for combustible dust environments
- UL 1598 wet location certification
- Rebate eligible for utility incentive programs
Frequently Asked Questions
What hazardous locations can this fixture handle?
This fixture is certified for Class 1 Division 2 Groups A, B, C, and D locations, as well as Class 2 Division 2 environments where combustible dust may be present under abnormal conditions.
How does the light output compare to fluorescent tubes?
With 7800 lumens and a 120-degree beam angle, this fixture typically provides superior illumination compared to traditional fluorescent linear fixtures while offering better color rendering at 70+ CRI.
What maintenance is required?
The 50,000-hour L70 lifespan and sealed IP66 construction minimize maintenance requirements. The 4kV surge protection helps prevent electrical damage in industrial environments.
Performance Overview
One of the reasons this fixture stands out is its combination of high efficiency and robust construction designed specifically for hazardous industrial environments. The 5000K color temperature provides clear visibility for detailed work, while the wide 120-degree beam distribution ensures comprehensive area coverage without harsh shadows or dark spots.
- Delivers 130 lumens per watt for exceptional energy efficiency
- Maintains stable light output across wide temperature ranges
- Provides instant-on operation without warm-up delays
- Features sealed die-cast aluminum housing for long-term durability
- Operates at 50-60Hz frequency for compatibility with standard electrical systems
Where This Fixture Excels
- Chemical processing facilities requiring Class 1 Division 2 compliance
- Paint spray booths and coating operations
- Grain handling and agricultural storage facilities
- Marine and offshore platform installations
- Manufacturing areas with potential gas or vapor presence
- Utility tunnels and industrial corridors
- Warehouse spaces storing flammable materials